| d | |
|
|
SUMMARY To measure the surrounding communities’ exposure to volatile organic compounds (VOCs) from the World Trade Center fires and cleanup activities, the State and City Health Departments collected air samples for some VOCs around the World Trade Center. Most of these compounds are commonly found in petroleum products or are common industrial chemicals. Some of these compounds are also produced by fires, including the World Trade Center fires, or by equipment, such as the equipment being used in the recovery effort. Air samples were taken on September 28, 2001 at three locations around the World Trade Center site. Samples were taken at roof level and street level. They were taken in the morning, afternoon and evening. One sample was also taken in the smoke at the wreckage at the World Trade Center. The sample in the smoke plume had the highest levels of VOCs. Recovery and emergency workers need to take safety measures that have been provided to them to limit their exposure to the smoke at the site. Samples were taken near Parc Place, Rector Place and Broadway at Liberty Streets. Upwind of the site and crosswind, levels of VOCs were about the same as those commonly found in outdoor samples (also called “background” levels). Downwind of the site, VOC levels for most of the compounds detected were higher than background. The higher levels of VOC compounds downwind of the site are not likely to last for an extended period of time (for example, the fires will be put out and the wind direction changes). The health risks from VOCs downwind, where the levels are highest, are still not much different than they would be for typical background levels. For the VOCs that were measured, the air concentrations outside the work area are not a significant health concern. However, other chemicals from the fires or other recovery activities may be contributing to eye, nose and throat irritation.
On September 28, 2001, New York State Department of Health (NYSDOH) and New York City Department of Health (New York City Department of Health Mental Hyigene) collected air samples at three locations north, southwest and southeast of the World Trade Center to measure community exposure levels to a limited number of VOCs. The locations were selected to represent the communities closest to the site that are currently occupied or might be expected to be re-occupied soon. The primary purpose was for screening, i.e. to determine whether additional VOC sampling in the surrounding community is warranted on some regular basis. The air samples were collected in Summa canisters over two hours at three locations, and a grab sample was taken on the rubble pile (see table below). The Summa canisters were returned to NYSDOH Wadsworth Laboratories for analysis by gas chromatography – mass spectrometry (GC-MS) following EPA method TO-14.
The day began sunny but became cloudy as the day progressed. A light rain started just before the evening sampling and was intermittent throughout that sampling period. Light winds were primarily from the north but shifted somewhat between the northeast and northwest throughout the day. Environmental Results and Conclusions
Data Limitations These VOCs were selected for analysis because they are commonly found at low levels in outdoor and indoor air, routine analytical procedures were readily available and many have been found in smoke. Other VOCs and semivolatile organic compounds have been found in the smoke from fires and can be expected near the site and in the smoke plume as well. Different sampling and analytical techniques are required for these compounds. Public Health Implications Although the highest levels of VOCs were found in samples from the plume at the WTC debris pile, these results are not likely to represent the potential exposure of the residents. Residents are unlikely to be in the plume at the debris pile where they could be exposed to these levels for any length of time. Therefore, the sampling results for areas potentially affected by the plume (i.e., at downwind locations) but not at the debris pile are more relevant for evaluating potential exposure to the residents. The levels of some of the chemicals in the plume measured at the debris are elevated and exceed typical background ranges, and recovery and emergency workers should take precautions to limit their exposure to emissions from the plume. The levels of VOCs at the upwind sites (75 Park Place and 225 Rector) are generally within the range of typical background levels. The air concentrations of VOCs at the downwind site (140 Broadway) were generally greater than those measured upwind (75 Park Place and 225 Rector) and typical background concentrations. However, none of the WTC-related chemicals measured at 140 Broadway exceed both typical background levels and air comparison values except benzene, chloromethane and styrene. None of the chemicals detected above background at 140 Broadway exceed intermediate or short-term air comparison values except benzene. The average and highest levels of benzene at 140 Broadway are slightly above typical background and are near the intermediate comparison value for this chemical. This comparison value for benzene is about 90 times lower than the exposure level that caused mild neurological effects in mice exposed regularly for 30 days. The benzene air concentrations at 140 Broadway (as well as typical background concentrations of benzene) exceed the health comparison value for benzene in air based on carcinogenic effects following long-term exposure. The cancer comparison value is the air concentration associated with an increased lifetime cancer risk of one-in-one million (10-6). Because the estimated duration of exposure is at most one year, and because elevated levels are unlikely to persist for extended periods of time (e.g. the fires will be put out and the wind direction will periodically change), community exposures are not expected to result in cancer risks that are appreciably increased over those resulting from background exposure. These estimated cancer risks do not exceed one-in-ten thousand (10-4), above which actions are usually taken to reduce exposure. The average levels of chloromethane and styrene also exceed background and their air comparison values based on cancer effects and long-term exposure. Again, based on the low potential for long-term exposure to elevated levels, this is not expected to result in an appreciable increased cancer risk, but one similar to the risks resulting from exposure to background levels. Limitations of Health Assessment The primary limitation of this assessment is that the list of VOCs measured may not be completely representative of the emissions from the fires and recovery activities at the World Trade Center site. The analytical methods did not include all of the numerous combustion products that can be generated from the fires, which, in addition to the measured VOCs, could affect air quality and public health. Some chemicals that are known to be produced by fires (e.g. aldehydes, acrolein) and that are strong respiratory irritants were not measured. When odors are present, it is not unusual for some people to experience short-term effects such as respiratory irritation and effects such as headaches and dizziness. These effects tend to diminish once exposure to the odors is stopped, and usually do not result in long-term health consequences. Some people are more likely to experience these effects than others. Conclusion The results of the monitoring suggest that the levels of some VOCs in the plume at the debris pile are significantly elevated above typical background levels, and workers at the site should take precautions to limit their exposure. For the VOCs that were measured, the air concentrations outside the work area are not a significant health concern. However, the elevation above background levels of some VOCs indicates that combustion products may be contributing to symptoms of eye, nose and throat irritation that have been reported in workers and residents in the WTC neighborhood. Based on the current results and the expected mitigation of VOC emissions from the site in the future by controlling the fires, continued monitoring for the VOCs sampled is not necessary at this time. However, it may be useful to confirm these findings, to assess levels of other volatile compounds such as known respiratory irritants and to assess VOC concentrations once the fires are controlled to ensure that other recovery activities are not a continuing source of VOCs in the community. References Peter S.J. Lees. 1995. Combustion products and other firefighter exposures: A state of the art review. Occup. Med. 10:691-706.
Notes:
| ||||||||||||||||||||||||||||||||
![]() |
Send questions or comments to: ceheduc@health.state.ny.us |
| Revised: November 2001 | |